From 468df96b0ff5d3bb3720e16f3f7b6e6dc2466cd2 Mon Sep 17 00:00:00 2001
From: esenapaj <esenapaj@users.noreply.github.com>
Date: Sun, 20 Mar 2016 20:57:14 +0900
Subject: [PATCH] follow-up the commit b82d91e

follow-up the commit b82d91eca69d87334530d874de79d85d06c54c2e
---
 Marlin/Configuration.h                                           | 1 +
 Marlin/example_configurations/Felix/Configuration.h              | 1 +
 Marlin/example_configurations/Felix/Configuration_DUAL.h         | 1 +
 Marlin/example_configurations/Hephestos/Configuration.h          | 1 +
 Marlin/example_configurations/K8200/Configuration.h              | 1 +
 .../RepRapWorld/Megatronics/Configuration.h                      | 1 +
 Marlin/example_configurations/RigidBot/Configuration.h           | 1 +
 Marlin/example_configurations/SCARA/Configuration.h              | 1 +
 Marlin/example_configurations/TAZ4/Configuration.h               | 1 +
 Marlin/example_configurations/WITBOX/Configuration.h             | 1 +
 Marlin/example_configurations/adafruit/ST7565/Configuration.h    | 1 +
 Marlin/example_configurations/delta/biv2.5/Configuration.h       | 1 +
 Marlin/example_configurations/delta/generic/Configuration.h      | 1 +
 Marlin/example_configurations/delta/kossel_mini/Configuration.h  | 1 +
 Marlin/example_configurations/delta/kossel_pro/Configuration.h   | 1 +
 Marlin/example_configurations/delta/kossel_xl/Configuration.h    | 1 +
 Marlin/example_configurations/makibox/Configuration.h            | 1 +
 Marlin/example_configurations/tvrrug/Round2/Configuration.h      | 1 +
 18 files changed, 18 insertions(+)

diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h
index 1d2e8a2800..a16ab17e2d 100644
--- a/Marlin/Configuration.h
+++ b/Marlin/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/Felix/Configuration.h b/Marlin/example_configurations/Felix/Configuration.h
index 8f12867ac6..9b81a7c5b0 100644
--- a/Marlin/example_configurations/Felix/Configuration.h
+++ b/Marlin/example_configurations/Felix/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/Felix/Configuration_DUAL.h b/Marlin/example_configurations/Felix/Configuration_DUAL.h
index 887ec8acb8..4e278c4f28 100644
--- a/Marlin/example_configurations/Felix/Configuration_DUAL.h
+++ b/Marlin/example_configurations/Felix/Configuration_DUAL.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/Hephestos/Configuration.h b/Marlin/example_configurations/Hephestos/Configuration.h
index 6a0b957093..918958425f 100644
--- a/Marlin/example_configurations/Hephestos/Configuration.h
+++ b/Marlin/example_configurations/Hephestos/Configuration.h
@@ -133,6 +133,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/K8200/Configuration.h b/Marlin/example_configurations/K8200/Configuration.h
index f8b17c6262..85fb621337 100644
--- a/Marlin/example_configurations/K8200/Configuration.h
+++ b/Marlin/example_configurations/K8200/Configuration.h
@@ -135,6 +135,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h b/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h
index 865e679e50..72bda37a8c 100644
--- a/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h
+++ b/Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/RigidBot/Configuration.h b/Marlin/example_configurations/RigidBot/Configuration.h
index 5f75947272..54a69115fb 100644
--- a/Marlin/example_configurations/RigidBot/Configuration.h
+++ b/Marlin/example_configurations/RigidBot/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/SCARA/Configuration.h b/Marlin/example_configurations/SCARA/Configuration.h
index 49563596e2..de3bc279f1 100644
--- a/Marlin/example_configurations/SCARA/Configuration.h
+++ b/Marlin/example_configurations/SCARA/Configuration.h
@@ -155,6 +155,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/TAZ4/Configuration.h b/Marlin/example_configurations/TAZ4/Configuration.h
index 660da82cad..61c8cd1f9a 100644
--- a/Marlin/example_configurations/TAZ4/Configuration.h
+++ b/Marlin/example_configurations/TAZ4/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/WITBOX/Configuration.h b/Marlin/example_configurations/WITBOX/Configuration.h
index 8dd0664dc9..272a0b1807 100644
--- a/Marlin/example_configurations/WITBOX/Configuration.h
+++ b/Marlin/example_configurations/WITBOX/Configuration.h
@@ -133,6 +133,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/adafruit/ST7565/Configuration.h b/Marlin/example_configurations/adafruit/ST7565/Configuration.h
index 77c9e3553f..f91f717092 100644
--- a/Marlin/example_configurations/adafruit/ST7565/Configuration.h
+++ b/Marlin/example_configurations/adafruit/ST7565/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/delta/biv2.5/Configuration.h b/Marlin/example_configurations/delta/biv2.5/Configuration.h
index 261e89ad30..65236758d7 100644
--- a/Marlin/example_configurations/delta/biv2.5/Configuration.h
+++ b/Marlin/example_configurations/delta/biv2.5/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/delta/generic/Configuration.h b/Marlin/example_configurations/delta/generic/Configuration.h
index 3d7999f483..620c0c4552 100644
--- a/Marlin/example_configurations/delta/generic/Configuration.h
+++ b/Marlin/example_configurations/delta/generic/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/delta/kossel_mini/Configuration.h b/Marlin/example_configurations/delta/kossel_mini/Configuration.h
index 905d4f0c50..336508ad1c 100644
--- a/Marlin/example_configurations/delta/kossel_mini/Configuration.h
+++ b/Marlin/example_configurations/delta/kossel_mini/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/delta/kossel_pro/Configuration.h b/Marlin/example_configurations/delta/kossel_pro/Configuration.h
index d32d1349ff..0971f3beca 100644
--- a/Marlin/example_configurations/delta/kossel_pro/Configuration.h
+++ b/Marlin/example_configurations/delta/kossel_pro/Configuration.h
@@ -134,6 +134,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/delta/kossel_xl/Configuration.h b/Marlin/example_configurations/delta/kossel_xl/Configuration.h
index 53d158f3d6..e87d1c86a3 100644
--- a/Marlin/example_configurations/delta/kossel_xl/Configuration.h
+++ b/Marlin/example_configurations/delta/kossel_xl/Configuration.h
@@ -153,6 +153,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/makibox/Configuration.h b/Marlin/example_configurations/makibox/Configuration.h
index 566ad7c92e..ac23be7c9c 100644
--- a/Marlin/example_configurations/makibox/Configuration.h
+++ b/Marlin/example_configurations/makibox/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
diff --git a/Marlin/example_configurations/tvrrug/Round2/Configuration.h b/Marlin/example_configurations/tvrrug/Round2/Configuration.h
index eebf57f636..65bdbabc4e 100644
--- a/Marlin/example_configurations/tvrrug/Round2/Configuration.h
+++ b/Marlin/example_configurations/tvrrug/Round2/Configuration.h
@@ -130,6 +130,7 @@ Here are some standard links for getting your machine calibrated:
 // 13 is 100k Hisens 3950  1% up to 300°C for hotend "Simple ONE " & "Hotend "All In ONE"
 // 20 is the PT100 circuit found in the Ultimainboard V2.x
 // 60 is 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
+// 70 is the 100K thermistor found in the bq Hephestos 2
 //
 //    1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
 //                          (but gives greater accuracy and more stable PID)
-- 
GitLab